What does "has fallen apart" mean in the ERC? [message #163133] Wed, 02 September 2015 17:02 Go to next message
Joerg
Messages: 742
Registered: October 2004
Senior Member
Hello,

Just got several statements like this as errors in the ERC:

"Segment of net /BLUE has fallen apart"

Yet those sections (two each) connect correctly and when clicked on are
still labeled correctly. And on the real product the blue LED lights
correctly :-)

It's Eagle 7.2. What gives? Is this a bug?

--
Regards, Joerg

http://www.analogconsultants.com/
Re: What does "has fallen apart" mean in the ERC? [message #163209 is a reply to message #163133] Mon, 07 September 2015 14:03 Go to previous messageGo to next message
CadSoft Support
Messages: 542
Registered: September 2006
Senior Member
Am 02.09.2015 um 19:02 schrieb Joerg:
> Hello,
>
> Just got several statements like this as errors in the ERC:
>
> "Segment of net /BLUE has fallen apart"
>
> Yet those sections (two each) connect correctly and when clicked on are
> still labeled correctly. And on the real product the blue LED lights
> correctly :-)
>
> It's Eagle 7.2. What gives? Is this a bug?
>


There seems to be a net that seems to consist of two segments but
should be only one segment. This is an tricky error message that
shouldn't occur...

To check this cold you ├╝please send the schematic file?

A solution could be to connect the two net segments in the schematic
and delete the connection again. But to be sure, we should look into
the file.

--
Mit freundlichen Gruessen / Best regards
Richard Hammerl
CadSoft Support -- hotline@cadsoft.de
FAQ: http://www.cadsoft.de/training/faq/
Re: What does "has fallen apart" mean in the ERC? [message #163253 is a reply to message #163209] Thu, 10 September 2015 17:38 Go to previous messageGo to next message
Joerg
Messages: 742
Registered: October 2004
Senior Member
On 2015-09-07 7:03 AM, Richard Hammerl wrote:
> Am 02.09.2015 um 19:02 schrieb Joerg:
>> Hello,
>>
>> Just got several statements like this as errors in the ERC:
>>
>> "Segment of net /BLUE has fallen apart"
>>
>> Yet those sections (two each) connect correctly and when clicked on are
>> still labeled correctly. And on the real product the blue LED lights
>> correctly :-)
>>
>> It's Eagle 7.2. What gives? Is this a bug?
>>
>
>
> There seems to be a net that seems to consist of two segments but
> should be only one segment. This is an tricky error message that
> shouldn't occur...
>

I always farm out layouts and most are done in PADS. The netlist was
correct and the boards are in series production.


> To check this cold you ├╝please send the schematic file?
>

I just sent it off to you and wrote the email in German so I don't
become rusty :-)


> A solution could be to connect the two net segments in the schematic
> and delete the connection again. But to be sure, we should look into
> the file.
>

In this case it could somehow be done but on more busy schematics where
that would require dozens of additional lines it isn't practical.

--
Regards, Joerg

http://www.analogconsultants.com/
Re: What does "has fallen apart" mean in the ERC? [message #170594 is a reply to message #163253] Mon, 29 May 2017 20:13 Go to previous message
Andreas Oelsner
Messages: 1
Registered: May 2017
Junior Member
Hallo zusammen,

what has been the solution? I got this problem already and ignored it. Meanwhile I have at least 5 different designs with that error message, it may be time to have a solid solution?

Best regards,
Andreas

--